Specifications:
1) Actual evaporation: 6MT/h
2) Pressure: 1.25MPa
3) Saturated steam temperature: 194
oC
4) Water supply temperature: 60
oC
5) Tested thermal efficiency: 81.12%
6) Outer size (L x W x H): 8.0 x 3.6 x 6.15m
7) Fuel category: soft coal II
The boiler is with a dual cylinder longitudinal structure and natural cycle methods
consisting of the upper components with the dominant main parts. The lower components
are primarily the combustion equipment. The two main parts can be instantly
installed and manufactured.
The boiler housing is with dense water exhaust cooling wall around the hearth. Partition
is mounted at the back of the hearth in front of the convection check and
forms the combustion ash room. Convection check is mounted at the back of the
combustion ash room. The smoke flows into the first and the second checks through
the combustion ash room and exhausts into the chimney through the coal saver and
dust catcher.
Structure:
1) Upper and lower cylinder diameter: φ 900mm
2) Cylinder central distance: 2,300mm
3) Left-right cabinet: φ219mm
4) Level central distance: 2,340mm
5) Hearth water cooling wall pitch: 53mm
6) Convection check distance: 90 x 120mm
7) The side wall is connected by 4 descending tubes leaded from the upper
cylinder
8) There are 4 φ108 x 4.5 descending tubes at each side of the lower
cylinder connected with the concentration cabinets
9) The boiler check and the water cooling wall are welded and connected
with the upper and lower cylinders
Combustion equipment:
1) Light chain-grate stoker
2) Width: 1,600mm
3) Effective area: 7.78m
2
4) Six independent wind storage cabinets
5) Dual-side air inlet ash door
6) Brick boiler arc
7) Front water cooling arc and level angle are 30
o
8) Outlet height: 1,013mm
9) Back arc outlet height: 764mm
10) Front-back arc coverage rates are 21% and 46.5%
11) The block wall is mounted at the upper outlet of the front arc to
increase the combustion room temperature and smoke flow
Design features:
1) After extensive selection, the vertical hose boiler is easily defined and
symmetrical facilitating manufacture and maintenance. It is with compact
size and low metallic consumption, great water capacity and large
convection heat transfer coefficient
2) To reduce the boiler wall weight, the side water cooling wall pitch is
densely structured and gets rid of the fire-bricks. Burial boiler wall
increases the air-tightness
3) Back arc and outlet block wall of the hearth are brick structured to
increase the temperature in addition to expanding the fuel application
4) Manhole is not installed in the combustion ash room. Smoke flow speed
may be increased appropriately, because the sole is mounted to exhaust
the ash to the lower grate
5) Front wall water cooling wall and descending tube are mounted to
increase the rigidity of the upper part
6) An aisle is reserved at the two sides of the convection check to reduce
dead corners and to facilitate maintenance
7) A hidden door is reserved at the back of the left side of the
second convection check. If necessary, the aisle can be reached through
the hidden door
8) Compressed shell, stylish design
9) Step-less motor and shift of the grates are necessary for the automatic
combustion
10) Equipped with multifunctional meter control panel; the inspection
display meter, the water supply automatic control panel, and the coal
combustion control panel are for manipulating rotating speed on the
operation table
11) Thermal data determination: subject to the determination of National
Industrial Boiler Product Quality Inspection Center, the heated surface
of the boiler is with reasonable configuration and large overload
capacity of more than 10%. The average efficiency is 81.12%